Assessment of the Tricuspid Valve Morphology by Transthoracic Real-Time-3D-Echocardiography
2005
Aim: To demonstrate the feasibility of transthoracic three-dimensional real-time echocardiography (3D-TTE) supplemental to routine assessments of the tricuspid valve and to analyze interrater agreement. Methods: Twenty healthy subjects and 74 patients with right ventricular failure were examined with conventional 2D and additionally 3D-TTE (SONOS 7500, Philips, Netherlands). The 3D exams were performed and recorded by one of two raters. The recordings were evaluated offline and independently by both raters for visualization of morphological and functional features of the tricuspid valve according to a subjective 3-point scale. Statistical analyses were performed for interrater agreement and…
Imaging Quality of Bifocal Piggyback Intraocular Lens versus ReSTOR and TECNIS Multifocal Lenses
2009
Purpose The imaging quality provided by a piggyback integrated by a monofocal intraocular lens (IOL) + a bifocal IOL of zero power and +3.75 diopters of addition is compared with the optics quality of a simple multifocal IOL of the same power and addition. Methods The imaging quality was evaluated by determining the modulation transfer function (MTF), using an artificial eye simulating in vivo conditions of the anterior chamber, including an artificial cornea and a wet cell containing physiologic solution where the IOL was positioned. The MTFs of the bifocal piggyback for near and distance vision were measured, with pupil diameters of 3 and 5 mm, and compared with the MTFs of an equivalent …
The Short-Access Mother–Baby-(SAMBA) Cholangioscopy System
2014
Conventional mother–baby cholangioscopy systems have significant limitations including poor image resolution, limited maneuverability and fragile cholangioscopes. We propose the novel short-access mother–baby-(SAMBA) cholangioscopy system that involves a very short and flexible cholangioscope that is introduced in a dedicated mother duodenoscope with an extra distal side port. Clinical feasibility of this device is demonstrated in three complex cases with cholangiopathies. The strengths of SAMBA cholangioscopy are improved imaging quality and excellent maneuverability of the baby that allows access of small intrahepatic ducts. Evaluation of suspected intrahepatic biliary disease is an excel…
Future Trends in Confocal Laser Endomicroscopy: Improved Imaging Quality and Immunoendoscopy
2007
Confocal laser endomicroscopy (CLE) is a powerful new technique that permits subsurface imaging at high resolution during ongoing endoscopy in the upper and lower GI tract [1]. Here, we will discuss future trends in CLE and their potential application in clinical practice. In particular, we will focus on molecular imaging using labelled antibodies for immunoendoscopy.
Hydro-MRT mit schnellen Sequenzen bei Morbus Crohn: Vergleich mit der fraktionierten Magen-Darm-Passage
2008
PURPOSE To compare the value of hydro-MRI with that of barium studies in patients with Crohn's disease. MATERIALS AND METHODS After an oral bowel opacification using 1000 ml of a 2.5% mannitol solution, axial and coronal breath-hold sequences (T2W HASTE +/- FS, contrast-enhanced T1W FLASH FS) were acquired in 46 patients with Crohn's disease at 1.0 T. The findings of hydro-MRI were compared with those of barium studies. RESULTS In the stomach and the small bowel, hydro-MRI and barium studies demonstrated similar numbers of Crohn's involvements (39 vs. 36); in the colon, hydro-MRI showed clearly more affections (23 vs. 10). Hydro-MRI showed 12.7 cm of inflamed bowel per patient, on average (…
Imaging quality of multifocal intraocular lenses: automated assessment setup
2012
[EN] Purpose: A new technique for the assessment of the optical quality of multifocal intraocular lenses (MIOLs) under monochromatic and polychromatic illumination is presented. Methods: The system provides, in a totally automated procedure, the modulation transfer function (MTF) of the lens under test for different axial positions of the object. The artificial eye admits different artificial corneas, to optimise the axial resolution in the sampling of the MTF of the MIOL under test, and different pupils, to test the dependence of the optical performance of the MIOL on the eye pupil diameter. Results: The performance and sensitivity of the apparatus is tested with different commercial MIOLs…